Is the breaker on?
The generator’s own main breaker and the utility breaker feeding the transfer switch. A unit that has been serviced or worked around recently is the usual case here.
A fault code, a unit that cranks and won’t start, a failed weekly exercise. Bring us the machine whoever put it in, and we’ll read it, tell you what it is, and tell you whether it’s worth repairing.
Not to talk you out of a service call — to make it a shorter one. Most no-starts come back to fuel, battery or a breaker, and knowing which before we arrive saves you diagnostic time.
The generator’s own main breaker and the utility breaker feeding the transfer switch. A unit that has been serviced or worked around recently is the usual case here.
A controller left in OFF or MANUAL after a service visit or a manual exercise will not start on an outage and will not tell you why until you look at it.
Write down the exact code or message. On a Generac an overcrank code points at fuel, battery or gas pressure long before it points at the engine.
Stop there. Do not open the enclosure, do not work on the gas connection, and do not attempt anything on the transfer switch or the panel. Those are line-voltage and fuel systems, and they are the reason this is licensed work.
Fuel or gas pressure first, then battery under load. An inadequate gas supply often only shows itself when the machine is asked to run, not on a self-test.
Commonly gas pressure or a failing battery that still passes the weekly test. Occasionally the transfer arrangement dropping the load back.
Battery, charger or the controller. A battery can read fine on a voltmeter and still fail to crank — it needs testing under load.
Almost always the battery, occasionally the charger. Worth acting on before an outage rather than after.
The transfer switch or the transfer arrangement itself. The engine side can be perfect while the building never actually gets power.
Extended run hours put the machine well outside its normal service interval. Oil, filters and coolant, then a full inspection.
A controller code narrows this considerably. If there is one on the display, read it to us on the phone.
Same day where we can, next day guaranteed. That is the promise, and it is deliberately a narrow one — it applies when you have no power and your set will not carry it, which is the situation that actually cannot wait.
Drive time is the constraint on everybody in the week after a named storm. We dispatch from Mosley Road in Houston near BW8, not from out of state.
Plan customers are worked in a timely manner, subject to weather and delays outside our control — and they are ahead of everyone without a plan in the queue.
In a normal week that difference is invisible. In the week after a storm it is the entire thing.
See maintenance plansWe read the controller, test the battery under load, check fuel and gas pressure, and exercise the transfer arrangement. You get told what it is and what it costs before anything is replaced.
If the machine is past economic repair, we say so. A service plan sold onto a unit that will not make the next season is worth nothing to either of us.
Yes, and a large share of our service work is exactly that — including units from installers who have gone quiet or gone out of business.
On Generac and Kohler, yes. We are factory-certified for both, we do the work and we file the claim ourselves.
There is 24/7 emergency dispatch with an on-call technician after hours. During a regional outage the queue is real and we will tell you honestly where you are in it.
We tell you. You get the cost of the repair against the cost of replacement, and we will price a replacement without pressure to take it.
Common service parts, yes. Model-specific components are ordered, and we will tell you the lead time rather than guess at it.
Flat batteries, old oil, a filter nobody changed. The weekly exercise cycle proves the engine starts — it does not prove the machine will carry the house for four days. Hurricane season runs June to November, and the queue fills the moment a system enters the Gulf.
Maintenance plans“During Hurricane Beryl, I stayed with my grandma who had a generator installed by Generator Industries… our power was out for a week. She was the only one who had power in our family and the generator worked phenomenally! … the lights went out for maybe 10 seconds before the generator kicked on.”
Mon–Fri 7:30 to 5:00 from our Houston office, and the on-call tech after hours.
Yes. We repair every major brand regardless of who put it in, including units installed by companies no longer trading. Our electricians are TECL-licensed and we are factory-certified for Generac and Kohler, so warranty work can be filed by us rather than sent elsewhere.
We run 24/7 emergency dispatch and we are based on Mosley Road in Houston, not out of state. In the week after a named storm, customers on a maintenance plan get priority scheduling ahead of the general queue.
Work through the three checks on this page first, breaker, AUTO switch and the display code, because a surprising number of no-starts are one of those three. If it is none of them, call us with the code on the display and we can usually tell you over the phone whether it needs a part or a visit.